Vol.13, No.2, May 2024.                                                                                                                                                                               ISSN: 2217-8309

                                                                                                                                                                                                                        eISSN: 2217-8333

 

TEM Journal

 

TECHNOLOGY, EDUCATION, MANAGEMENT, INFORMATICS

Association for Information Communication Technology Education and Science


Performance Analysis of an Incremental Conductance MPPT Algorithm for Photovoltaic Systems Under Rapid Irradiance Changes

 

Asnil Asnil, Refdinal Nazir, Krismadinata Krismadinata, Muhammad Nasir Sonni

 

© 2024 Refdinal Nazir, published by UIKTEN. This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. (CC BY-NC-ND 4.0)

 

Citation Information: TEM Journal. Volume 13, Issue 2, Pages 1087-1094, ISSN 2217-8309, DOI: 10.18421/TEM132-23, May 2024.

 

Received: 13 November 2023.

Revised:   14 February 2024.
Accepted: 28 February 2024.
Published: 28 May 2024.

 

Abstract:

 

The control algorithm for tracking the maximum power point (MPPT) is a crucial factor that influences the system's capacity to harness the maximum energy from the sun using photovoltaic. Incremental conductance stands out as one of the most commonly employed MPPT techniques due to its simplicity and low implementation complexity. However, it has various shortcomings, rendering it less effective in adapting to changing solar radiation conditions. Therefore, this study proposed a modification to enhance the algorithm's performance. The proposed modified algorithm is validated through experiments, revealing that the fastest tracking time for the adjusted incremental conductance algorithm was 72 ms, whereas the unmodified algorithm took 84 ms. Additionally, oscillations observed during changes in radiation values were 2 W and 1.66 W for the unmodified algorithm, occurring during decreases and increases in radiation values, respectively. In contrast, the proposed modified incremental conductance algorithm resulted in a consistent oscillation of 1.33 W for each change in radiation value.Furthermore, it can be concluded that the modified incremental conductance algorithm can increase the tracking time as well as reduce oscillations that occur under various conditions of changes in radiation values.

 

Keywords –Incremental conductance, MPPT, tracking performance, solar radiation, boost converter.

 

-----------------------------------------------------------------------------------------------------------

Full text PDF >  

-----------------------------------------------------------------------------------------------------------

 


Copyright © 2024 UIKTEN
Copyright licence: All articles are licenced via Creative Commons CC BY-NC-ND 4.0 licence