Vol.9, No.1, February 2020.                                                                                                                                                                           ISSN: 2217-8309

                                                                                                                                                                                                                        eISSN: 2217-8333

 

TEM Journal

 

TECHNOLOGY, EDUCATION, MANAGEMENT, INFORMATICS

Association for Information Communication Technology Education and Science


Factors Affecting the Performance of Fresh Water Generator in Merchant Vessel

 

Hartanto Hartanto, Agus Tjahjono, Okvita Wahyuni, Edi Wibowo

 

© 2020 Agus Tjahjono, published by UIKTEN. This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. (CC BY-NC-ND 4.0)

 

Citation Information: TEM Journal. Volume 9, Issue 1, Pages 19‐24, ISSN 2217-8309, DOI: 10.18421/TEM91-03, February 2020.

 

Received: 08 November 2019.

Revised:   28 January 2020.
Accepted:  05 February 2020.
Published: 28 February 2020.

 

Abstract:

 

The research was aimed (1) to analyze the effect of distillate pump performance on the performance of fresh water generator; (2) to analyze the effect of ejector pump performance on the performance of fresh water generator; and (3) to investigate the effect of distillate pumps and ejector pumps joint performance on the performance of fresh water generator. The data were obtained through questionnaire of 67 students who had completed their one year shipboard training on merchant vessels. The data were analyzed using SPSS statistics 16.0 version. The results showed that the variable of distillate pump performance positively affected the performance of fresh water generator reaching 39%. The variable of ejector pump performance also positively affected the performance of fresh water generator reaching 43.5%. The independent variables of this research were the performance of the distillate pump (X1) and the ejector pump (X2) which jointly affected the performance of the water generator reaching 60.5%.

 

Keywords –distillate pump performance, ejector pump performance, fresh water generator performance.

 

-----------------------------------------------------------------------------------------------------------

Full text PDF >  

-----------------------------------------------------------------------------------------------------------

 


Copyright © 2012-2020 UIKTEN, All Rights reserved
Copyright licence: All articles are licenced via Creative Commons CC BY-NC-ND 4.0 licence